Skip to content

R Series Ruggedized Partially Depleted Silicon Radiation Detector

Main Application
Charged-particle spectroscopy in vacuum or in air with ambient light; cleanable.
  • Literature +

  • Mounting Arrangements +


    Mount must be specified when ordering.

    A
     This is a "ring mount"; i.e., the silicon wafer is offered on its ring without output connectors. 

    B  Microdot connector on the rear of the can.

    C  BNC connector on the rear of the can.

    T  Microdot on the side of the can; without adjustable screws.

    Dimensions are given in millimeters.

    §Built into a Microdot connector only.


    Detector Size (mm2)

    W (Nominal)
    Type A  Type B Rear Microdot Type C Rear BNC  TypeT§ Transmission
    X Y  X Y Z X Y Z X Y Z
     050  8.0 15.2 3.7
    16.7 12.3 7.1 16.7 12.3 15.9 19.4 7.9 9.9
     150  13.8 22.0 3.7
    23.6 12.3 7.1 23.6 12.3 15.9 26.1 7.9 9.9
     300  19.5 27.1 3.7
    28.6 12.3 7.1 28.6 12.3 15.9 31.6 7.9 9.9
     450 23.9 30.5 3.7
    32.0 12.3
    7.1 32.0 12.3
    15.9 34.8 7.9 9.9
     600  27.6 34.1 3.7 36.1 12.3 7.1 36.1 12.3 15.9 38.4 7.9 9.9
     900  33.9 43.2 3.7 45.2 12.3 7.1 45.2 12.3 15.9      
     2000 51.0      65.5 12.3 7.1 65.5 12.3 15.9      
     Tolerance ±0.5 ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3
    ±0.3 ±0.3 ±0.3
  • Ordering Information +


    Mount must be specified when ordering.

    Supplied with B Mount unless otherwise specified.

    *Supplied in B Mount unless specified otherwise by the appropriate letter prefix. Other areas, depths, and configurations available on special order.

    **First three digits of Model No. indicate total system resolution FWHM for 241AM, 5.486-MeV alphas, using standard ORTEC electronics and 0.5-µs shaping time constants. Beta resolution approximated by pulse generator width FWHM.

    NOTE: Alpha Suite Compatible Detectors: ULTRA-AS and Low-Background R Series detectors in B-mount are guaranteed compatible with the Alpha Suite products (DUO, MEGA, ARIA, ENSEMBLE).  All other detectors require an approved special for compatibility and warranted specifications.


    Active
    Area
    (mm2)
    Guaranteed Maximum
    Resolution** (keV)
    Minimum Resolution
    Depth 100 µm
    Minimum Resolution
    Depth 300 µm
     
    α β Model No. Model No. 
    50 15
    17
    7
    8
    R-015-050-100
    R-017-050-100
    R-015-050-300
    R-017-050-300
    150 16
    19
    10
    11
    R-016-150-100
    R-019-150-100
    R-016-150-300
    R-019-150-300
    300 19
    21
    13
    15
    R-019-300-100
    R-021-300-100
    R-019-300-300
    R-021-300-300
    450 20
    24
    14
    19
    R-020-450-100
    R-024-450-100
    R-020-450-300
    R-024-450-300
    600 25
    33
    17
    28
    R-025-600-100
    R-033-600-100
    R-025-600-300
    R-033-600-300
    900 30
    40
    25
    35
    R-030-600-100
    R-040-600-100
    R-030-600-300
    R-040-600-300
    2000 50
    60
    45
    55
    R-050-2000-100
    R-060-2000-100
    R-050-2000-300
    R-060-2000-300


    Active
    Area
    (mm2)
    Guaranteed Maximum
    Resolution** (keV)
    Minimum Resolution
    Depth 500 µm
    α β Model No.
    50 15
    17
    7
    8
    R-015-050-500
    R-017-050-500
    150 16
    18
    10
    11
    R-016-150-500
    R-018-150-500
    300 19
    21
    13
    15
    R-019-300-500
    R-021-300-500
    450 20
    24
    14
    18
    R-020-450-500
    R-024-450-500
    600 25
    33
    19
    29
    R-025-600-500
    R-033-600-500
    900 30
    53
    25
    48
    R-030-600-500
    R-053-600-500
    2000 50
    80
    45
    75
    R-050-2000-500
    R-080-2000-500
  • Ordering Information - Low Background "See No Alpha" for Alpha Spectrometers +


    **First three digits of Model No. indicate total system resolution FWHM for 241AM, 5.486-MeV alphas, using standard ORTEC electronics and 0.5-µs shaping time constants. Beta resolution approximated by pulse generator width FWHM.

    NOTE: Alpha Suite Compatible Detectors: ULTRA-AS and Low-Background R Series detectors in B-mount are guaranteed compatible with the Alpha Suite products (DUO, MEGA, ARIA, ENSEMBLE).  All other detectors require an approved special for compatibility and warranted specifications.


    Active
    Area
    (mm2)
    Minimum Resolution
    Depth 100 µm
    Minimum Resolution
    Depth 100 µm
     
    Model No.  Model No.
    300 TR-SNA-300-100 BR-SNA-300-100 
    450 TR-SNA-450-100 BR-SNA-450-100 
    600 TR-SNA-600-100  BR-SNA-600-100
     900  N/A  BR-SNA-900-100