Skip to content

HPGe Radiation Detector Options and Accessories

  • Detector Add-on Options +


    Integrated Cryocooling System Option (-ICS, -ICS-E)
    The Integrated Cryocooling System (ICS) cryostat is sealed with a cryocooler and is immune to thermal short cycling. Unlike the typical three day loss of use of the detector with a standard type cryostat, the ICS can be re-cooled immediately, minimizing any time lost for temporary warm up. The ICS is available with an internal preamplifier (-ICS) or an external preamplifier (-ICS-E). 
    Compatible Detector Types for -ICS: GEM
    Compatible Detector Types for -ICS-E: GEM, PROFILE, GMX

    Integrated Cryocooling Low-Background System  (-ICS-LB)
    Low-background detector with internal preamplifier, high purity aluminum endcap, high purity aluminum window, high purity aluminum internal cup, and low-background Cu mount for the ICS Integrated Cryocooling System. The lower background material allows for lower Minimum Detectable Activity (MDA) for a specific counting time, which provides another step in increasing sample throughput in low-background applications.
    Compatible Detector Types: GEM

    SMART-1 Option  (-SMP, -SMN)
    The SMART-1 option monitors and reports on vital system functions, and can save authentication codes and report the code at a later time. It has the high voltage included, so none of the instruments require an external high-voltage power supply. The SMART-1 is housed in a rugged ABS molded plastic enclosure and is permanently attached to the detector endcap via a molded-strain-relieved sealed cable. This eliminates the possibility that the detector will suffer severe damage from moisture leaking into high-voltage connectors. The SMART-1 can be positioned in any convenient place and does not interfere with shielding or other mounting hardware.
    Compatible Detector Types for -SMP: GEM, PROFILE, Safeguards GEM, Actinide-85
    Compatible Detector Types for -SMN: GMX, GLP, Safeguards GLP

    Ultra-High Count-Rate Preamplifier Option  (-PL)
    The Ultra-High Count-Rate Preamplifier (transistor-reset preamplifier), can handle input count rates up to 1,000,000 counts/s at 1 MeV and offers the added benefit of having no feedback resistor.
    Compatible Detector Types: GEM, PROFILE, GMX

    Harsh Environment Option  (-HE)
    The Harsh Environment option is a rugged carbon fiber endcap with a sealed electronics housing featuring a replaceable desiccant pack which ensures that the electronics stay 100% dry and indicates when it needs to be replaced. GEM series detectors in PopTop capsules of 76 mm diameter or larger can be supplied with this option. 
    Compatible Detector Types: GEM, PROFILE, GMX

    Remote Preamplifier Option  (-HJ)
    This option allows all the preamplifier and high voltage connections to be outside a shield and removes the preamplifier and high voltage filter from the “line-of-sight” to the Ge crystal. For low background applications, this option eliminates any possible preamplifier or high voltage filter components that may add to the background inside a shield.
    Compatible Detector Types: GEM, PROFILE, GMX, GWL

    Low-Background Carbon Fiber Endcap Options  (-RB, -LB-C, and -XLB-C)
    The Low-Background Carbon Fiber Endcap is as strong as Al, Mg, and Cu, creates less background, does not corrode, and can detect energies less than 10 keV. This lower background material allows for lower Minimum Detectable Activity (MDA) for a specific counting time, which provides another step in increasing sample throughput in low-background counting applications. The lower Z of Carbon Fiber provides a low-energy window without the additional background found in most alloys.
    Compatible Detector Types: GEM, PROFILE, GMX

    Beryllium Window Options  (-B)
    Provides improved performance between 3 and 5 keV.
    Compatible Detector Types: PROFILE

    Aluminum Window Option  (-A)
    An all aluminum endcap can be chosen if the energies of interest exceed 20 keV. 
    Compatible Detector Types: GMX

    Carbon Fiber Window Option  (-CW)
    A carbon fiber window is available for energies greater than about 8 keV. While this window does not pass all the lower energies, carbon fiber has lower Z than Al and does not have any of the hazards associated with Be.
    Compatible Detector Types: GMX

    Low-Background Well  (-LB-AWT, and -XLB-AWT)
    Low-background Well detectors are supplied with oxygen-free high conductivity (OFHC) copper endcaps with low-background high purity aluminum well tubes of 0.02 inch wall thickness.
    Compatible Detector Types: GWL
  • Lead Shields +


    HPLBS High Performance Low Background Lead Shield for Radiation Detector 
    HPLBS
    High Performance Low Background Shields
    HPULBS High Performance Ultra Low Background Lead Shield for Radiation Detector
    HPULBS High Performance Ultra Low Background Lead Shields
           
  • Other Accessories +


    HT-1 Heater Tape 
    HT-1 heater tape
    Detector Interface Module (DIM) (SMART-1) (SMART-INTERFACE)
    Detector Interface Modules (DIM) or (SMART-INTERFACE and SMART-1)
    469 for use with ORTEC Radiation Detectors and other manufacturer's HV supplies
    469 For use with ORTEC Detectors with other manufacturer’s HV supplies equipped with shutdown circuitry with HV-on in open circuit condition and HV-off in short circuit condition. Includes adapter cable.
    SENSADPTR need to connect vent line to Multi Orientation (MOD) Dewar
    SENSADPTR needed to connect a vent line to the multi-orientation (MOD) dewars.
    PTPA need to adapt VVO-2 to access vacuum in ORTEC PopTop Radiation Detector 
    PTPA is one of two items needed to adapt the model VVO-2 to access the vacuum in PopTop capsules.
     PTVSO used to adapt VVO-2 to access vacuum in ORTEC PopTop Radiation Detector
    PTVSO is one of two items needed to adapt the model VVO-2 to access the vacuum in PopTop capsules.
    TL liquid nitrogen transfer line 
    TL-3, 6, 9, 12, 15, 18, 21, and 24 liquid nitrogen transfer lines supplied in respective lengths (ft.).
    [Terminated on one end with a 3/8" to 3/8" union and with a 1/2" SAE 45 degree fitting on the other end.]
    VL liquid nitrogen vent line
    VL-6, 9, 12, 15, 18, 21, 24, and 30 vent lines for liquid nitrogen filling supplied in respective lengths (ft.)
    496 Heater Tape Temperature Control  
    496D used to control the temperature of heater tapes.
    496D-1 includes the 496 and HT-1.
    496D-2 includes the 496, HT-1, and SDT-1.
     596A Temperature Controller  
    596-A temperature controller for internal heating elements inside special cryostats.
    729A Liquid Nitrogen Level Monitor 
    729A Liquid Nitrogen Level Monitor
    Dewar
    DWR-30 30-Liter Dewar 
    DWR-30-OP 30-Liter Offset Port Dewar
    STD 50L 50-Liter Dewar
    SDT-1 Step Down Transformer
    SDT-1 220V/110V step down transformer.
    810292 Sieve Pill pumping agent for ORTEC PopTop Radiation Detector vacuum interface 
    810292 or "Sieve Pill" pumping agent for the PopTop vacuum interface.
    VVO-1 adapts VVO-2 to access vacuum in ORTEC Streamline Radiation Detectors
    VVO-1 adapts the VVO-2 to access the vacuum in Non-PopTop cryostats.
    VVO-2 vacuum valve operator and the tooling for any ORTEC Radiation Detector vacuum connection
    VVO-2 vacuum valve operator and the ORTEC tooling for any ORTEC vacuum connection. (May require adapters.)
    Cryosecure Compressor Power Controller 
    Cryosecure compressor power controller.
     
    B/PFA for Pressure Filling Dewar 
    B/PFA-1.2, 3.0, or 5.0 used to pressure fill portable dewars with respective volumes.
    CRE Cooling Rod Extension 
    CRE-1 4-in. Cooling Rod Extension; used on dipstick detectors. Includes indium foil gasket.
    Fill Funnel for filling Portable Dewar
    Fill Funnel for filling portable dewars are provided with portable detector systems with different length fill tubes according to the dewar size.
    WD Withdrawal Device
    WD-30 and WD-50 withdrawal device supplied in respective dewar size. Dewar not included.
    LNP Probe for 729A
    LNP-7D Probe for use with 729A; fits standard 7.5-liter and 13 liter bucket (SL, PS, PS4) type dewars.
    LNP-30B is longer with a slightly different lid.

    LNP-30 Probe for 729A 
    LNP-30D-2 Probe with LN2 transfer collar for use with 729A. Fits 1.5-inch diameter cryostat (e.g., CFG-PH4, CFG-PV4). Requires DWR-30 or DWR-30-OP.
    LNP-30D-3 Probe with LN2 transfer collar for use with 729A. Fits 1.25-inch diameter cryostat (e.g., CFG-SH, CFG-SV). Requires DWR-30 or DWR-30-OP.
    NTC/30 for Pressure
    NTC/30 (pictured) used for pressure filling the 30L bucket style dewar.
    Models NTC/7.5B, NTC/13, and NTC/15B are for respective dewar sizes.
    NTC for pressure filling dewar
    PFB-MOD3L and PFB-MOD7L pressure fill adapters for the respective sized multi-orientation dewars.
    LNTC Liquid Nitrogen Transfer Collar
    LNTC1.5R 1.5" Liquid Nitrogen Transfer Collar with mounting hardware.

    CFG-ADAPTOR to increase cryostat diameter 
    CFG-ADAPTOR Adaptor to increase cryostat diameter from 1.25 inch to 1.5 inch