Skip to content

RADEAGLE State-of-the-Art Hand-Held, Radioisotope Identification Device

RADEAGLE State-of-the-Art Hand-Held, NaI Radioisotope Identification Device
  • Combining a large, high sensitivity crystal with an intelligent algorithm, the RADEAGLE can quickly, accurately, and simultaneously detect and identify four or more isotopes, typically in under 30 seconds.
  • ANSI 42.34 compliant, the RADEAGLE offers a user-friendly interface that is intuitive, simple to navigate, provides visually clarity, and utilizes an extensive array of alarms.
  • Supports a variety of scintillation crystals including NaI(Tl), CeBr3 and LaBr3(Ce) to optimize performance across multiple applications.
  • Incorporating decades of industry expertise in detection and identification algorithms along with advanced hardware, electrical, and software systems, the RADEAGLE is the hand-held RIID of choice.
  • Literature +

  • Video +

  • More Information +


    RADEAGLE is a state-of-the-art handheld, radioisotope identification device (RIID) delivering superior speed and accuracy.

    Key Customers and Applications
    • First Responders and Emergency Management
    • Customs and Border Protection
    • Security and Military Forces
    • Nuclear Safeguards
    • Environmental Management and Cleanup
    • Nuclear Medicine and Scientific Institutes
    • Scrap Steel and Recycling

    Intelligent Algorithm – Unparalleled Speed and Accuracy

    The RADEAGLE algorithm is unique, using a neuron ensemble to create a multi-agent system. This multi-agent system in turn uses a mimetic learning algorithm that adapts reference data to the unique signature of the detector’s sensors. While continuously measuring background radiation, this “neuro-spectroscopic brain,” delivers unparalleled speed and accuracy for detecting and identifying over 100 nuclides, exceeding ANSI 42.34 requirements.  

    Operating Modes
    The RADEAGLE uses five basic operating modes: Dose Rate, Detect, Easy-ID, Spectrum, and Advanced. These five simple modes gives the user full system control ranging from quick and accurate identification to extensive spectrum analysis to expert system configurations. 

    Application Centric Approach
    A key benefit of the RADEAGLE algorithm is its optimization for multiple real-world applications. Through extensive simulation, validated and refined with real world empirical testing, the RADEAGLE’s performance is tuned and optimized for key isotopes associated with SNM in the nuclear security and safeguards market, NORM and IND for environmental and industrial applications and MED for nuclear medicine. Underwater measurements are also supported with a submersible, NaI model.

    RADEAGLE Aqua State-of-the-Art Hand-Held, Radioisotope Identification Device for Water ApplicationsRADEAGLE AQUA
    • IP 68
    • Submersible to 15 meters
    • Tested and proven ID algorithm with special modification to compensate for attenuation and scatter in water
    • Floats in the water
    • Rugged and durable for military use
    • Bright yellow color for easy location in water
    • Ideal for use in maritime environments — immune to salt spray
  • Specifications +


    Specifications Common to All Models

    Radiological Performance
    Energy Range/MCA 11 keV to 3 MeV / 2048 channels
    Calibration Source
    Natural background. Optional embedded calibration source. 
    Nuclide Library
    Default Isotopes:
    110mAg, 241Am, 133Ba, 207Bi, 109Cd, 252Cf (requires neutron detection), 57Co, 60Co, 51Cr, 134Cs, 137Cs, 152Eu, 68Ga, 123I, 125I, 131I, 111In, 40K, 54Mn, 99Mo2, 22Na, 237Np, 238Pu, 239Pu, (240Pu, 241Pu as part of compositions) 226Ra, 75Se, 99mTc, 232Th, 201Tl, 233U, 235U, 238U

    Optional Isotopes (contact factory):
    109mAg, 198Au, 135mBa, 140Ba, 213Bi, 116Cd, 58Co, 139Ce, 141Ce, 144Ce, 131Cs, 64Cu, 67Cu, 165Dy, 18F, 59Fe, 67Ga, 68Ge, 166mHo, 124I, 132I, 133I, 194Ir, 42K, 81mKr, 138La, 140La, 173Lu, 174Lu, 176Lu, 177Lu, 177mLu, 56Mn, 24Na, 95Nb, 96Nb, 147Nd, 212Pb, 103Pd, 144Pr, 82Rb, 186Re, 188Re, 106Rh, 103Ru, 106Ru, 153Sm, 113Sn, 82Sr, 89Sr, 90Sr, 132Te, 228Th, 44Ti, 202Tl, 204Tl, 232U, 237U, 187W, 131mXe, 133Xe, 133mXe, 135Xe, 88Y, 90Y, 169Yb, 177Yb, 65Zn, 95Zr
    Nuclide Categories
    Special nuclear material (SNM), Naturally occurring radiation (NORM), Industrial emitter (IND), or Medical source (MED)

    Physical
    Dimensions 248 mm x 115 mm x 152 mm (9.8” x 4.5” x 6.0”)
    Display
    640 x 480, 89 mm (3.5”) Transflective Color TFT
    Batteries
    Rechargeable AA NiMH battery pack, auxiliary battery case for AA NiMH or alkaline
    Operational Run Time
    >8 hours with standard battery pack

    Environmental
    Operating Temperature –20 °C to +50 °C (–4 °F to +122 °F )
    Relative Humidity
    10% – 90%, non-condensing
    Protection Rating
    IP65, submersible to 15 meter for models 3SGA and 3SGA-H

    Computational
    Memory >16 GB (1,000,000 spectra)
    CPU Speed
    1 GHz
    File Formats
    ANSI N42.42, SPE (IAEA)
    Connectivity
    USB, WiFi, GPS (optional)

    Software
    Operating System Microsoft Windows (XP, Vista, 7, 8, 10), MAC OS X Yosemite, Linux (tested for Ubuntu)

    Model Specific Specifications
    Model Detector Type Detector Dimensions PMT GM He3 Resolution @ 662 keV 137Cs at ambient room temp Sensitivity cps/µSv/h @ 662 keV 137Cs Dose Rate Range Detector µSv/h Dose Rate Range GM, up to Sv/h Weight (g)
    RADEAGLE-3SG
    NaI(Tl)
    76.2x25.4 mm (3x1 in)
    3”
    x

    ≤7.2%
    >2500
    0.01–200
    1
    ~2620
    RADEAGLE-3SG-H
    NaI(Tl)
    76.2x25.4 mm (3x1 in)
    3”
    x x ≤7.2%
    >2500
    0.01–200
    1
    ~2720
    RADEAGLE-3SGA
    NaI(Tl)
    76.2x25.4 mm (3x1 in)
    3”
    x
    ≤7.2%
    >2500
    0.01–200
    1
    ~2620
    RADEAGLE-3SGA-H NaI(Tl) 76.2x25.4 mm (3x1 in)
    3”
    x x ≤7.2%
    >2500
    0.01–200
    1
    ~2720
    RADEAGLE-2CG CeBr3 50.8x25.4 mm (2x1 in)
    3”
    x
    ≤4.0%
    >1600
    0.01–300
    1
    ~2200
    RADEAGLE-2CG-H CeBr3 50.8x25.4 mm (2x1 in)
    3”
    x x ≤4.0%
    >1600
    0.01–300
    1
    ~2620
    RADEAGLE-3CG CeBr3 76.2x20.3 mm(3x0.8 in)
    3”
    x
    ≤4.0%
    >2500
    0.01–200
    1
    ~2620
    RADEAGLE-3CG-H CeBr3 76.2x20.3 mm(3x0.8 in)
    3”
    x x ≤4.0%
    >2500
    0.01–200
    1
    ~2720
    RADEAGLE-2LG LaBr3(Ce) 50.8x25.4 mm (2x1 in)
    3”
    x
    ≤3.0%
    >1600
    0.01–300
    1
    ~2250
    RADEAGLE-2LG-H LaBr3(Ce) 50.8x25.4 mm (2x1 in)
    3”
    x x ≤3.0%
    >1600
    0.01–300
    1
    ~2250
  • Ordering Information +


    All models include carrying case and accessories.
    Model  Description
    RADEAGLE-3SG Gamma Handheld RIID with 3x1 NaI(Tl) detector and GM tube.
    RADEAGLE-3SG-ES Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube and embedded calibration source.
    RADEAGLE-3SG-GPS Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube and GPS.
    RADEAGLE-3SG-GPS-ES Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube, GPS and embedded calibration source.
    RADEAGLE-3SG-H Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, and He-3 detector.
    RADEAGLE-3SG-H-ES Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector and embedded calibration source.
    RADEAGLE-3SG-H-GPS Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector and GPS.
    RADEAGLE-3SG-H-GPS-ES Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector, GPS and embedded calibration source.
    RADEAGLE-3SGA Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube and underwater option.
    RADEAGLE-3SGA-ES Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube, underwater option and embedded calibration source.
    RADEAGLE-3SGA-GPS Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube, underwater option and GPS.
    RADEAGLE-3SGA-GPS-ES Gamma Handheld RIID with 3x1 NaI(Tl) detector, GM tube, underwater option, GPS and embedded calibration source.
    RADEAGLE-3SGA-H Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector and underwater option.
    RADEAGLE-3SGA-H-ES Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector, underwater option and embedded calibration source.
    RADEAGLE-3SGA-H-GPS Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector, underwater option and GPS.
    RADEAGLE-3SGA-H-GPS-ES Gamma/Neutron Handheld RIID with 3x1 NaI(Tl) detector, GM tube, He-3 detector, underwater option, GPS and embedded calibration source.
    RADEAGLE-2CG Gamma Handheld RIID with 2x1 CeBr3 detector and GM tube.
    RADEAGLE-2CG-ES Gamma Handheld RIID with 2x1 CeBr3 detector, GM tube and embedded calibration source.
    RADEAGLE-2CG-GPS Gamma Handheld RIID with 2x1 CeBr3 detector, GM tube and GPS.
    RADEAGLE-2CG-GPS-ES Gamma Handheld RIID with 2x1 CeBr3 detector, GM tube, GPS and embedded calibration source.
    RADEAGLE-2CG-H Gamma/Neutron Handheld RIID with 2x1 CeBr3 detector, GM tube and He-3 detector.
    RADEAGLE-2CG-H-ES Gamma/Neutron Handheld RIID with 2x1 CeBr3 detector, GM tube, He-3 detector and embedded calibration source.
    RADEAGLE-2CG-H-GPS Gamma/Neutron Handheld RIID with 2x1 CeBr3 detector, GM tube, He-3 detector and GPS.
    RADEAGLE-2CG-H-GPS-ES Gamma/Neutron Handheld RIID with 2x1 CeBr3 detector, GM tube, He-3 detector, GPS and embedded calibration source.
    RADEAGLE-3CG Gamma Handheld RIID with 3x0.8 CeBr3 detector and GM tube.
    RADEAGLE-3CG-ES Gamma Handheld RIID with 3x0.8 CeBr3 detector, GM tube and embedded calibration source.
    RADEAGLE-3CG-GPS Gamma Handheld RIID with 3x0.8 CeBr3 detector, GM tube and GPS.
    RADEAGLE-3CG-GPS-ES Gamma Handheld RIID with 3x0.8 CeBr3 detector, GM tube, GPS and embedded calibration source.
    RADEAGLE-3CG-H Gamma/Neutron Handheld RIID with 3x0.8 CeBr3 detector, GM tube and He-3 detector.
    RADEAGLE-3CG-H-ES Gamma/Neutron Handheld RIID with 3x0.8 CeBr3 detector, GM tube, He-3 detector and embedded calibration source.
    RADEAGLE-3CG-H-GPS Gamma/Neutron Handheld RIID with 3x0.8 CeBr3 detector, GM tube, He-3 detector and GPS.
    RADEAGLE-3CG-H-GPS-ES Gamma/Neutron Handheld RIID with 3x0.8 CeBr3 detector, GM tube, He-3 detector, GPS and embedded calibration source.
    RADEAGLE-2LG Gamma Handheld RIID with 2x1 LaBr3(Ce) detector and GM tube.
    RADEAGLE-2LG-GPS Gamma Handheld RIID with 2x1 LaBr3(Ce) detector, GM tube and GPS.
    RADEAGLE-2LG-H Gamma/Neutron Handheld RIID with 2x1 LaBr3(Ce) detector, GM tube and He-3 detector.
    RADEAGLE-2LG-H-GPS Gamma/Neutron Handheld RIID with 2x1 LaBr3(Ce) detector, GM tube, He-3 detector and GPS.
    Accessories  
    RE-AP009-1 Accu-Pack with battery (spare)
    RE-AP009-2 Accu-Pack without battery (battery holder only)
    RE-CA019 Auto Power Adapter, 12 V
    RE-CC022 Carrying Case
    RE-CM020 Charger Module
    RE-HB021 Carry Holster with Strap