576A Dual Alpha Spectrometer
  • Two independent alpha-spectroscopy channels
  • Each channel includes vacuum chamber, sample holder, detector, bias supply,
    preamplifier, amplifier, biased amplifier, test pulser, and discriminator
  • Separate energy range selections for each channel: 3-5, 4-6, or 5-7 MeV and
    3-7, 4-8, or 5-9 MeV
  • Choice of either vertical or horizontal sample holder
  • Available with ULTRA™ or Ruggedized® detector with area of 300 mm2,
    450 mm2, or 600 mm2
  • Precalibrated at the factory, the 576A requires no further adjustments
  • AlphaVision-32 (A36-B32) is recommended as companion alpha analytical software

The Model 576A Dual Alpha Spectrometer is a self-contained, double-wide NIM
module that contains two independent alpha-spectroscopy channels. Each
channel includes a vacuum chamber, a choice of either a vertical or horizontal
sample holder, and ORTEC ULTRA low-background, ion-implanted silicon detector
or a Ruggedized low-background surface barrier detector (300-mm2, 450-mm2, or
600-mm2 detectors are available), a detector bias supply, a preamplifier, a shaping
and stretching amplifier, a biased amplifier, a test pulser, and a discriminator
(Fig.1). The unit is factory calibrated, and no further adjustments are necessary.

By a simple jumper selection on the side panel and a front-panel energy range
switch, each channel can be set so that the output range represents energies from
3 to 5, 4 to 6, or 5 to 7 MeV in the 2-MeV position; and from 3 to 7, 4 to 8, or 5 to
9 MeV in the 4-MeV position. Another simple jumper selection sets the internal
pulser signal at the center of the appropriate range (Fig.2).

Together with a vacuum pump and a multichannel analyzer, the Model 576A
provides a complete reliable, easy-to-operate, low-level dual alpha spectroscopy
system. Eight- or sixteen-channel alpha spectroscopy systems can easily be
configured by utilizing the ORTEC Model 920E 16-Input Multichannel Buffer.

The special ULTRA or Ruggedized low-background detectors supplied with each
Model 576A Dual Alpha Spectrometer have been processed through the standard
ORTEC quality control procedures. To eliminate the possibility of low-level alpha
contamination, these detectors have not been exposed to alpha particles. Instead,
alpha resolution is measured on a representative sample of detectors from each
batch of ULTRA or Ruggedized low-background detectors produced to ensure that
the specified alpha resolution is met. The alpha resolution and noise resolution are
measured in accordance with IEEE Standard 300-1998. (Ruggedized detectors
are tested at a 0.5 µs amplifier shaping time constant, ULTRA detectors at 1.0 µs).

Figure 1. Simplified Block Diagram of One Channel of the Model 576A Dual Alpha Spectrometer.

Figure 2. Side Panel Energy Range and Test Pulser Selection.

Ordering Information

When purchasing detectors separately, please indicated "for use with Model 576A Dual
Alpha Spectrometer" on your purchase order, and specify the geometrical configuration
desired (vertical or horizontal). Detector extraction tools are not supplied with this model.
 

Model Description
576A-XXXV 576A module without Detectors; Vertical Sample Holder
576A-XXXH 576A module without Detectors; Horizontal Sample Holder
with ULTRA-AS Detectors
576A-300UV Vertical 576A module with two 300-mm2 ULTRA-AS
576A-450UV Vertical 576A module with two 450-mm2 ULTRA-AS
576A-600UV Vertical 576A module with two 600-mm2 ULTRA-AS
576A-300UH Horizontal 576A module with two 300-mm2 ULTRA-AS
576A-450UH Horizontal 576A module with two 450-mm2 ULTRA-AS
576A-600UH Horizontal 576A module with two 600-mm2 ULTRA-AS
with Ruggedized Detectors
576A-300RV Vertical 576A module with two R-Series (300-mm2 , 100µm deep)
576A-450RV Vertical 576A module with two R-Series (450-mm2 , 100µm deep)
576A-600RV Vertical 576A module with two R-Series (600-mm2 , 100µm deep)
576A-300RH Horizontal 576A module with two R-Series (300-mm2 , 100µm deep)
576A-450RH Horizontal 576A module with two R-Series (450-mm2 , 100µm deep)
576A-600RH Horizontal 576A module with two R-Series (600-mm2 , 100µm deep)
  • Vertical models include two 576-SHAV-K sample holder assembly kits (unless other sample holders are requested) and one 576-DETV detector extraction tool.
  • Horizontal models include two 576-HTH horizontal sample tray holders, two 576-HT horizontal sample trays, and one 576-DETH detector extraction tool.

Accessories and Sample Holder Assemblies

Model Description
576-DETH Horizontal Detector Extraction Tool
576-DETV Vertical Detector Extraction Tool
576-HTH Horizontal Sample Tray Holder
576-HT Horizontal Sample Tray
576-OVC Spare O-Rings
576-SHAV-S Customized Sample Holder
576-SHAV-K Sample Holder Kit (includes 576-SHAV-1, 576-SHAV-2, 576-SHAV-4, and 576-SHAV-5)
576-SHAV-1 Vertical Sample Holder (for use with 1" x 0.025" thick flat metal planchet)
576-SHAV-2 Vertical Sample Holder (for use with 1.25" x 0.025" thick flat metal planchet)
576-SHAV-3 Vertical Sample Holder (for use with 25-mm filter paper)
576-SHAV-4 Vertical Sample Holder (for use with 37-mm filter paper)
576-SHAV-5 Vertical Sample Holder (for use with .75" x 0.025" thick flat metal planchet)
576-VCD Vacuum Chamber Door

 

  Sample Holder Dimensions
(Diameter)
Retaining Ring Dimensions
(Diameter)

Model

A B C D
576-SHAV-1 1.500 1.010 1.555 .910
576-SHAV-2 1.500 1.260 1.555 1.160
576-SHAV-3 1.000 No C Bore 1.055 0.890
576-SHAV-4 1.500 No C Bore 1.555 1.390
576-SHAV-5 1.000 0.765 1.055 0.670