576A Dual Alpha Spectrometer
- Two independent alpha-spectroscopy channels
- Each channel includes vacuum chamber, sample holder, detector, bias supply,
preamplifier, amplifier, biased amplifier, test pulser, and discriminator
- Separate energy range selections for each channel: 3-5, 4-6, or 5-7 MeV and
3-7, 4-8, or 5-9 MeV
- Choice of either vertical or horizontal sample holder
- Available with ULTRA or
Ruggedized® detector with area of 300 mm2,
450 mm2, or 600 mm2
- Precalibrated at the factory, the 576A requires no further adjustments
- AlphaVision-32 (A36-B32) is recommended as
companion alpha analytical software
The Model 576A Dual Alpha Spectrometer is a
self-contained, double-wide NIM
module that contains two independent alpha-spectroscopy channels.
Each
channel includes a vacuum chamber, a choice of either a vertical or
horizontal
sample holder, and ORTEC ULTRA low-background, ion-implanted silicon
detector
or a Ruggedized low-background surface barrier detector (300-mm2,
450-mm2, or
600-mm2 detectors are available), a detector bias supply,
a preamplifier, a shaping
and stretching amplifier, a biased amplifier, a test pulser, and a
discriminator
(Fig.1). The unit is factory calibrated,
and no further adjustments are necessary.
By a simple jumper selection on the side panel and a front-panel
energy range
switch, each channel can be set so that the output range represents
energies from
3 to 5, 4 to 6, or 5 to 7 MeV in the 2-MeV position; and from 3 to
7, 4 to 8, or 5 to
9 MeV in the 4-MeV position. Another simple jumper selection sets
the internal
pulser signal at the center of the appropriate range (Fig.2).
Together with a vacuum pump and a multichannel analyzer, the Model
576A
provides a complete reliable, easy-to-operate, low-level dual alpha
spectroscopy
system. Eight- or sixteen-channel alpha spectroscopy systems can
easily be
configured by utilizing the ORTEC
Model 920E 16-Input
Multichannel Buffer.
The special ULTRA or Ruggedized low-background detectors supplied
with each
Model 576A Dual Alpha Spectrometer have been processed through the
standard
ORTEC quality control procedures. To eliminate the possibility of
low-level alpha
contamination, these detectors have not been exposed to alpha
particles. Instead,
alpha resolution is measured on a representative sample of detectors
from each
batch of ULTRA or Ruggedized low-background detectors produced to
ensure that
the specified alpha resolution is met. The alpha resolution and
noise resolution are
measured in accordance with IEEE Standard 300-1998. (Ruggedized
detectors
are tested at a 0.5 µs amplifier shaping time constant, ULTRA
detectors at 1.0 µs).
 Figure 1.
Simplified Block Diagram of One Channel of the Model 576A Dual Alpha
Spectrometer. 
Figure 2. Side Panel Energy Range
and Test Pulser Selection. Ordering Information When
purchasing detectors separately, please indicated "for use with
Model 576A Dual
Alpha Spectrometer" on your purchase order, and specify the
geometrical configuration
desired (vertical or horizontal). Detector extraction tools are
not supplied with this model.
| Model |
Description |
| 576A-XXXV |
576A module
without Detectors; Vertical Sample Holder |
| 576A-XXXH |
576A module
without Detectors; Horizontal Sample Holder |
| with
ULTRA-AS Detectors |
| 576A-300UV |
Vertical 576A
module with two 300-mm2 ULTRA-AS |
| 576A-450UV |
Vertical 576A
module with two 450-mm2 ULTRA-AS |
| 576A-600UV |
Vertical 576A
module with two 600-mm2 ULTRA-AS |
| 576A-300UH |
Horizontal
576A module with two 300-mm2 ULTRA-AS |
| 576A-450UH |
Horizontal
576A module with two 450-mm2 ULTRA-AS |
| 576A-600UH |
Horizontal
576A module with two 600-mm2 ULTRA-AS |
| with
Ruggedized Detectors |
| 576A-300RV |
Vertical 576A
module with two R-Series (300-mm2 , 100µm deep) |
| 576A-450RV |
Vertical 576A
module with two R-Series (450-mm2 , 100µm deep) |
| 576A-600RV |
Vertical 576A
module with two R-Series (600-mm2 , 100µm deep) |
| 576A-300RH |
Horizontal
576A module with two R-Series (300-mm2 , 100µm deep) |
| 576A-450RH |
Horizontal
576A module with two R-Series (450-mm2 , 100µm deep) |
| 576A-600RH |
Horizontal
576A module with two R-Series (600-mm2 , 100µm deep) |
- Vertical models include two 576-SHAV-K sample holder
assembly kits (unless other sample holders are requested) and
one 576-DETV detector extraction tool.
- Horizontal models include two 576-HTH horizontal sample tray
holders, two 576-HT horizontal sample trays, and one 576-DETH
detector extraction tool.
Accessories and Sample Holder Assemblies
|
Model |
Description |
|
576-DETH |
Horizontal
Detector Extraction Tool |
|
576-DETV |
Vertical
Detector Extraction Tool |
|
576-HTH |
Horizontal
Sample Tray Holder |
|
576-HT |
Horizontal
Sample Tray |
|
576-OVC |
Spare O-Rings |
|
576-SHAV-S |
Customized
Sample Holder |
|
576-SHAV-K |
Sample Holder
Kit (includes 576-SHAV-1, 576-SHAV-2, 576-SHAV-4, and
576-SHAV-5) |
|
576-SHAV-1 |
Vertical
Sample Holder (for use with 1" x 0.025" thick flat metal
planchet) |
|
576-SHAV-2 |
Vertical
Sample Holder (for use with 1.25" x 0.025" thick flat metal
planchet) |
|
576-SHAV-3 |
Vertical
Sample Holder (for use with 25-mm filter paper) |
|
576-SHAV-4 |
Vertical
Sample Holder (for use with 37-mm filter paper) |
|
576-SHAV-5 |
Vertical
Sample Holder (for use with .75" x 0.025" thick flat metal
planchet) |
|
576-VCD |
Vacuum
Chamber Door |
| |
Sample Holder Dimensions
(Diameter) |
Retaining Ring Dimensions
(Diameter) |
|
Model
|
A |
B |
C |
D |
| 576-SHAV-1 |
1.500 |
1.010 |
1.555 |
.910 |
| 576-SHAV-2 |
1.500 |
1.260 |
1.555 |
1.160 |
| 576-SHAV-3 |
1.000 |
No C Bore |
1.055 |
0.890 |
| 576-SHAV-4 |
1.500 |
No C Bore |
1.555 |
1.390 |
| 576-SHAV-5 |
1.000 |
0.765 |
1.055 |
0.670 |

|