| Home | Site Map | Contact Us | ||
| Products | Service | New on Site | ||
|
|
Technical Papers Archive Topics: High Purity Germanium Detector Applications and Technology DevelopmentsNuclear Safeguards Applications General Gamma Spectrometry Waste AssayTime Spectrometry and Timing Applications MiscellaneousHigh Purity Germanium Detector Applications and Technology Developments
Advances in Germanium
Detector Technology R.M. Keyser and T.R. Twomey, ORTEC (Presented at HPS Annual Meeting, June 2002, Tampa, Florida)
Recent
Developments in HPGe Material and Detectors for Gamma-Ray Spectroscopy
R. Keyser, T. Twomey, and P. Sangsingkeow, EG&G ORTEC (1999)
A
Low Profile Monolithic Multi-Element Ge Detector for X-Ray Fluorescence
Applications R.M. Keyser, T.R. Twomey, and P. Sangsingkeow (1998)
A New Apparatus for Surface X-Ray Adsorption and Diffraction
Studies Using Synchrotron Radiation
A
Solid State Detector for Soft Energy Extended X-Ray Absorption Fine Structure Measurements Nuclear Safeguards Applications
Recent
Developments of the MGA++ Codes
Recent
Developments of LANL PC/FRAM Code
Application
of X-Ray K-Edge Densitometry in D&D Operations General Gamma Spectrometry Characteristics
of High-Rate Energy Spectroscopy Systems Using HPGe Coaxial Detectors and Time-Variant
Filters Advances in Analysis Software
Comparison of
Alternative Methods for Multiplet Deconvolution in the Analysis of Gamma-Ray Spectra
(Abstract) R.M. Keyser, ORTEC
Library-Directed
Versus Peak-Search-Based Gamma-Ray Analysis Waste Assay Developments in High-Performance HPGe Detector Spectrometer Systems for Safeguards ApplicationsR.M. Keyser and T.R. Twomey (1997) Evaluation
of a Standard, Commercially-Available Gamma Spectroscopy System for High-Rate Waste
Management Applications R. Hagenauer, Martine Marietta Energy Systems (1991 INMM)
Non-Destructive
Assay Quantification of Poorly Characterized Radioactive Isotopes Time Spectrometry and Timing Applications
FastFlight,
Digital Signal Averager for Continuous High-Speed Data Acquisition with Electrospray
Time-of-Flight Mass Spectrometers Coupled to Chromatographs
Determination
of Atmospheric Ozone Profiles at 68N and 79N with a Daylight Lidar Instrument
A New
High Rate Positron Lifetime Measurement System M.O. Bedwell and T.J. Paulus, ORTEC (1978)
Design of the
Constant Fraction of Pulse Height Trigger for Optimum Time Resolution D.A. Gedcke and C.W. Williams (1968)
A Constant
Fraction of Pulse Height Trigger for Optimum Time Resolution
Characterization
of Room Temperature Detectors Using the Proposed IEEE Standard |