ANTECH Series 200
High Sensitivity Large Sample Calorimeter

  • nda7.gif (12511 bytes)Absolute measurement of sample thermal power
  • Comprehensive User friendly windows based User Interface Software
  • Reduced Criticality hazard as water is not used as a heat sink
  • Measurement times with equilibrium sample power prediction of between 2-4 hours
  • Total mass of Pu determined with error propagation when Pu isotopic data is provided on a file or ‘on-line’ from ANTECH Pu Gamma-ray Isotopic Measurement System
  • Comprehensive and traceable electrical calibration capability reduces dependence on Pu standards
  • Highly transportable trolley mounted system
  • The transportability of the instrument allows the user to move the calorimeter to the measurement site and thus limits the need to move special nuclear material. At the same time, instrument transportability does not compromise measurement accuracy. The design has application to a wide range of measurement requirements including international safeguards measurements, shipper-receiver difference measurements, in-plant accountancy measurements and anomaly resolution in passive neutron coincidence counting or segmented gamma-ray scanning. The instrument also has a role in replacing a proportion of destructive assay.

    The modular transportable design facilitates installation, maintenance and the use of the instrument in a variety of measurement applications. In the standard configuration, the calorimeter is capable of measuring plutonium bearing samples which can be contained in a cylindrical canister with internal dimensions 190.5 mm (7.70 in) in diameter and 355.6 mm (14.0 in) high. The calorimeter has a variable sample power measurement range from below 0.025 to 20 watts and an operating temperature range from 20 to 50°C.

    Variations to the standard design for different requirements and for special sample types or sample packaging can be accommodated. In particular the measurement chamber volume may be reduced or increased in size and measurement precision and measurement time may be optimized for a specific limited sample power range. Smaller sample diameter custom systems achieve significantly better precision and accuracy at lower measurement powers (e.g. <10 mW).

    Specifications
  • Thermal power measurement accuracy better than 0.5% over the operating range and better that 0.2% at 1.0 Watts power (7.5” diameter sample)
  • Variable Measurement Chambers operating temperature range from 20 to 50°C
  • Measurement range from 20 mW to 50 Watts
  • Instrument footprint 123 cm x 69 cm x 147 cm (L x W x H), overall height of the removable hoist is 187 cm
  • Weight of trolley mounted version is approximately 300 kg
  • Power consumption 300-600 watts 110/230 V AC
  • Measurements approved for use by IAEA and WIPP