ORTEC Logo

 
Home | Applications | Contact Us
Products | Service | Training

  Application Guide for Timing and Counting with Fast Discriminators

These charts are intended as selection guides only. For complete and precise specifications, consult the data sheet for each model.

Application Discriminator Model Number
CF8000 583B 584 935 9302 9307 9327
Scintillation Detectors CFD CFD, SCA CFD CFD AMP/LE    
Silicon Charged-Particle Detectors CFD CFD, SCA CFD CFD AMP/LE    
Microchannel Plates, Microchannel Plate PMTs, Channeltrons     LE (CFD) LE pT pT
Single-Photon Counting/Timing with Photomultiplier Tubes CFD CFD, SCA CFD CFD LE pT pT
Germanium Detectors ARC ARC, SRT, SCA ARC, SRT ARC      
Fast Photodiodes     LE (CFD) LE pT pT

Slection Guide for Fast Discriminators

Model Number of Channels Package Width Max. Burst Rate Pulse Pair Resolving Time Modes Selectable Fractions Shaping Delay Special Notes

CF8000

8

NIM-1

20 MHz

50 ns

CFD, ARC

0.4

Internal, selectable

Auto-walk adjust, special outputs

583B

1

NIM-1

20 MHz

50 ns

SCA, CFD, ARC, SRT, BKO

0.2

External cable

Upper and lower level discriminators

584

1

NIM-1

50 MHz

20 ns

CFD, ARC, SRT, LE, BKO

0.2

External cable

Min. threshold = 5 mV, Input gate

935

4

NIM-1

200 MHz

5 ns

CFD, ARC, (LE), BKO

0.2

External cable

Accepts input widths as short as 1 ns. Individual gates and common veto.

9302

1

NIM-1

100 MHz

10 ns

LE

   

Fast amplifier and LE discriminator. See Amplifier section.

9307

1

NIM-1

100 MHz

10 ns

pT

   

Optimized for single-photon and single-ion timing with microchannel plate/PMTs.

9327

1

Preamp

100 MHz

10 ns

pT

   

Optimized for single-photon and single-ion timing with microchannel plate detectors. Also fast photodiodes and fast PMTs. Includes 1-GHz amplifier.

Codes:
AMP = Includes fast amplifier
ARC = Amplitude and rise time compensated timing
BKO = Blocking output
CFD = Constant-fraction discriminator mode

LE = Leading-edge discriminator mode
SCA = Single-channel analyzer (upper and lower level discriminators)
SRT = Slow rise time rejection option
pT = pico-Timing discriminator