Download PDF
|
449/449-2 Log/Lin RatemeterSpecificationsPERFORMANCE LINEAR RANGES 11 ranges from 10 to 106 counts/s full scale in 1-3-10 steps. Dead Time <100 ns on the 106 range; <0.3% of average pulse spacing up to the 3 X 104 range; £1% on the 105 and 3 X 105 ranges. Rated Overload Maintains full-scale output for X300 overload or 107 counts/s, whichever is smaller. Temperature Instability <±0.05%/°C. Nonlinearity £±0.15% from 10 to 3 X 104 counts/s range; £±1.5% from 105 to 106 counts/s. Time Constants 7 selectable time constants, 0.03 to 30 s in 1-3-10 steps. Zero Suppression 0 to 100% of full scale; nonlinearity of £±0.25%. LOGARITHMIC RANGE One 5-decade range for 10 to 106 counts/s. Temperature Instability £±0.25% of full scale per °C. Analog Output Error £±2.5% of full scale. Standard Deviation ~15% with Log Short time constant; ~5% with Log Long time constant. Slewing Rate Dependent on input rate; for any rate change. Log Short time constant provides 10 times faster response than Log Long time constant. CONTROLS RANGE 12-position switch selects the full-scale range and either linear or logarithmic mode; linear ranges are 0 to 10 counts/s through 0 to 106 counts/s in 1-3-10 steps; log range is 10 to 106 counts/s. TIME CONSTANT 9-position switch selects an integrating time constant of 0.03, 0.1, 0.3, 1, 3, 10, or 30 s for linear ranges from 10 to 3 X 104 counts/s or for any of these values divided by 10 for 105, 3 X 105, and 106 ranges; Short and Long for the log range. ZERO SUPPRESSION 10-turn precision potentiometer to suppress the zero-reference level for any linear range from 0 to 100%; the same full-scale span is effective above the preselected zero-reference level. INPUTS Accepts either positive or negative input signals with amplitude ³±3 V and width ³50 ns; ±30 V maximum; UG-1094/U BNC connectors on both front and rear panels. OUTPUTS PANEL METER 240° circular movement with 8.9 cm (3.5 in.) deflection; accuracy 2% of full scale; three scale markings, 01 and 03 for linear ranges and 10106 in five decades for log range. ANALOG OUTPUT 0 to +10 V full scale, dc-coupled with 100-W output impedance; UG-1094/U BNC connector on rear panel. RECORDER OUTPUT (A) Voltage output with 100-mV full scale; dc-coupled with 100-W output impedance; binding post connectors on rear panel. RECORDER OUTPUT (B) Current output with 1-mA full scale; dc-coupled with 10-kW output impedance; binding post connectors on rear panel. OPTION 449-2 AUDIBLE OUTPUT OPTION This option is in addition to the regular specifications of Model 449. AUDIO OUTPUT A tone of variable frequency is furnished through a chassis-mounted speaker; the frequency increases from essentially 0 to 500 Hz, corresponding to the proportional meter deflection. AUDIO THRESHOLD A 1-turn control mutes the audible output until the input rate exceeds the setting of the control and permits the output to be heard for all higher rates; range is 0 to 100% of selected full scale, linear, and log. AUDIO VOLUME A 1-turn control adjusts the amplitude of the audible output from a near-inaudible level to a level that can be heard above normal laboratory ambient noise. ELECTRICAL AND MECHANICAL POWER REQUIRED +24 V, 50 mA; 24 V, 35 mA; +12 V, 30 mA; 12 V, 45 mA. WEIGHT DIMENSIONS NIM-standard double-width module 6.90 X 22.13 cm (2.70 X 8.714 in.) per DOE/ER-0457T. ORDERING INFORMATION
|