GWL Series Germanium (HPGe) Well Detectors

For analysis of small, low-activity samples
  • Ultimate absolute counting efficiency for small samples
  • Active Volumes to 400 cc
  • Unique ion-implanted blind well
  • Resolution specified with source inside the well
  • Spectroscopy from 10 keV to 10 MeV
  • Near 4 geometry
  • Extra-large well (1.55 X 4.0 cm) standard

b29.jpg (10306 bytes)

Figure 29. Simplified Isometric View of
HPGe Well Detector Cryostat.

b30.jpg (16778 bytes)

Figure 30. Absolute Detection Efficiency in the
Well vs. Photon Energy. [If a well detector is used
as a general-purpose coaxial detector (a use not
 recommended by ORTEC), its relative efficiency at
25 cm can be determined from the equation.]

ORTEC’s High-Purity Germanium (HPGe) Well Detectors offer the ultimate absolute counting efficiency for radiochemical analysis and low-level gamma-ray spectroscopy. The unique ion-implanted detector well has an ultra-thin dead layer (only 0.3 µm thick), and therefore provides the most extensive useful energy range (10 keV to 10 MeV). Unlike other Well detectors that have a hole all the way through the germanium crystal, ORTEC’s Well Detectors have a "blind hole" with at least 5 mm of active germanium at the bottom of the hole (Fig. 29). This near 4- geometry provides the maximum absolute counting efficiency available. The large well (1.55-cm-diam and 4.0-cm-long) accommodates an extensive range of sample sizes. Like all of ORTEC’s HPGe photon detectors, the HPGe Well detector may be stored or cycled repeatedly to room temperature without performance degradation. Well detectors, not available in PopTop capsule, can be supplied in these "streamline" cryostats:

Vertical or horizontal dipstick and side-looking or J "bucket."

As specified in ANSI/IEEE Std. 325-1996, the resolution is measured with a point source inside the well, 1 cm from the bottom. Measurements of resolution outside the well can be deceiving.

A typical curve of absolute efficiency in the well vs. photon energy is shown in Fig. 30.

For large, dilute samples (such as water, soil, grass, etc.), the GAMMA-X detector, used with a Marinelli beaker, is the optimal choice.

 

Ordering Information

GWL Series Germanium (HPGe) Well Detector — NOT Available in PopTop Capsules.

Model No.

Active
Volume
(cc)

Well
Diameter*
(mm)

Well
Depth*
(mm)

Energy Resolution FWHM

End Cap
Diameter
(mm)

at 1.33 MeV
(keV)

at 122 keV
(keV)

GWL-90-10

90

10

40

2.10

1.2

70

GWL-90-15

90

15.5

40

2.30

1.4

70

GWL-110-10

110

10

40

2.10

1.2

70

GWL-110-15

110

15.5

40

2.30

1.4

70

GWL-120-10 **

120

10

40

2.10

1.2

70

GWL-120-15 **

120

15.5

40

2.30

1.4

70

GWL-130-10

130

10

40

2.10

1.2

70

GWL-130-15

130

15.5

40

2.30

1.4

70

GWL-150-10

150

10

40

2.10

1.2

83

GWL-150-15

150

15.5

40

2.30

1.4

83

GWL-170-10

170

10

40

2.10

1.2

83

GWL-170-15

170

15.5

40

2.30

1.4

83

GWL-190-10

190

10

40

2.10

1.2

83

GWL-190-15

190

15.5

40

2.30

1.4

83

GWL-220-10

220

10

40

2.10

1.2

95

GWL-220-15

220

15.5

40

2.30

1.4

95

GWL-250-10

250

10

40

2.10

1.2

95

GWL-250-15

250

15.5

40

2.30

1.4

95

GWL-280-10

280

10

40

2.15

1.2

95

GWL-280-15

280

15.5

40

2.30

1.4

95

GWL-300-10

300

10

40

2.15

1.2

95

GWL-300-15

300

15.5

40

2.30

1.4

95

GWL-350-10

350

10

40

2.15

1.2

95

GWL-350-15

350

15.5

40

2.30

1.4

95

GWL-400-10

400

10

40

2.15

1.2

108

GWL-400-15

400

15.5

40

2.30

1.4

108

GWL-450-10

450

10

40

2.15

1.2

108

GWL-450-15

450

15.5

40

2.30

1.4

108

*Larger detectors (up to 450 cc) and other well dimensions are available on special order.
**Note GWL-120 is standard order and delivery, all others are special order only.