SLP Series Silicon Lithium-Drifted [Si(Li)] Planar Low-Energy X-Ray Detectors (in PopTop Capsule) For x-ray spectroscopy with a nuclear accelerator, radioactive source, or x-ray tube
The x-ray detector consists of a lithium-drifted silicon crystal and a cryogenically-cooled-FET, a high-gain, low-noise hybridized preamplifier in a PopTop capsule with a thin Be entrance window. The ORTEC Si(Li) detector crystal is manufactured under an exclusive process. Special techniques for lithium drifting result in a negligible detector element dead layer whose characteristics will not change even if the detector is stored at room temperature. The SLP Series Si(Li) detector provides exceptional resolution performance. A pulsed optical feedback preamplifier having and energy rate in excess of 4000 MeV/s* is supplied with the SLP Series detectors.An ultra-thin Be window (either 0.3 mil and 0.5 mil) is an option. SLP detectors have an exclusive high-rate indicator and high-voltage shutdown protection feature. If the LN2 supply is exhausted and the detector begins to warm while high voltage is applied, the high voltage will automatically shut off, thus protecting the FET from damage.As a single element or in multiple detector arrays (Figs. 26 and 27), the SLP Series has become an important tool in soft x-ray spectroscopy in fusion research. Please contact the factory or your local sales representative for specific information on these applications. An SLP PopTop detector consists of:(a) A Si(Li) detector element (Fig. 28) mounted, in most systems, inside the vacuum enclosure of its PopTop capsule. (b) A charge-sensitive preamplifier and a HV filter, with accompanying cable pack. The first stage of the preamplifier is also mounted inside the vacuum enclosure to ensure proper cooling for optimum noise and reliability. The second stage of the preamplifier and HV filter are part of the PopTop assembly but reside outside the vacuum enclosure to which they are connected by vacuum feedthroughs.(c) A dipstick cryostat with a 30-liter LN2 dewar or a combination cryostat-dewar assembly. All SLP detectors are supplied with a Pulsed-Optical-Feedback (POF) preamplifier.Consult Factory for appropriate electronics for SLP detectors. *The POF does not "lock up" or saturate at high count rates, unlike resistor-feedback designs. At ultra-high count rates with the POF, throughput is limited by reset pulse rates. 4000 MeV/s is an estimate of maximum "useable" energy rate. Ordering InformationSLP Silicon (Li) X-Ray Detector in PopTop Capsule
* Unless otherwise specified, each Si(Li) detector is supplied with a 25 µm (0.001 in.) thick Be window, except on the 16-mm-diameter unit, which has a 50 µm (0.002 in.)-thick Be window. OPT0.3 is supplied with a 8 µm (0.0003 in.)-thick Be (ultra-thin) unsupported window for 4-mm-diameter detectors. OPT0.5 is supplied with a 13 µm (0.0005 in.)-thick Be window for 4- and 6-mm-diameter detectors. |