LO-AX
Germanium (HPGe) Low-Energy Photon Detector
The LO-AX provides optimum peak-to-background ratio from 10 to 400 keV
on large-area samples. It is also ideal for in vivo actinide monitoring using L x
rays.
- Large active area
- 36-, 51-, 60-, and 70-mm diameter available
- Ideal for in vivo actinide monitoring
- Excellent for uranium monitoring
- PopTop flexibility
- ULTRA-thin rugged Ion-implanted pointer contact sensitive at front and sides
The LO-AX is a large active area, "short" coaxial detector
which supplies the best possible energy resolution for the energy range from 3 to 400 keV.A typical application for the LO-AX is in vivo quantitative
actinide monitoring. This measurement, frequently performed in the past using phoswich
scintillation counters, is now routinely performed using a LO-AX, usually in a
low-background cryostat.

Figure 21. Dimensional Drawing of the
51-mm-Diameter
LO-AX Detector Element. |

Figure 22. Low Energy Gamma and X-Ray Transmission
of Be and Carbon Fiber Windows. |
The LO-AX detector element length, about one-half that of the diameter
(Fig. 21), provides a special, low-capacitance coaxial geometry. The result is 370-eV
energy resolution at 5.9 keV for the 51-mm diameter LO-AX detector. Typical measured
resolution for 13- to 17-keV x rays is ~400 eV. Higher efficiency is available with
the 60-mm and 70-mm-diameter LO-AX detectors.Because of their good energy resolution at low energies LO-AX detectors,
particularly in low-background cryostats, are ideal for quantifying plutonium. In most
laboratories 70-mm diameter LO-AX have become the detector of choice because of their
higher efficiency and sensitivity. An additional benefit of the 70-mm detector is a net
reduction in Compton background due to the increased probability that a high energy event
will experience a multiple interaction in the larger detector, and thus generate a count
in a channel well above the Pu peak.
The LO-AX detectors wide energy range results in high efficiency
for the quantification of uranium.
The LO-AX is equipped with an automatic, high-voltage shutdown
capability.
LO-AX detectors are available with a choice of Be or carbon fiber window.
Transmission data is shown in Fig. 22.
Ordering Information
LO-AX Germanium (HPGe) Coaxial Low-Energy Photon Spectrometer in PopTop Capsule*
A complete detector assembly requires a cryostat and a dewar.
|
Model No. |
Detector
Diameter
(mm) |
Area
(mm2) |
Dimensions
Depth
(mm) |
Energy Resolution
FWHM ** |
|
@ 5.9 keV |
@ 122 keV |
| LX-36300-15P4 |
36 |
1000 |
15 |
300 |
550 |
| LX-51370-20P4 |
51 |
2000 |
20 |
370 |
625 |
| LX-60450-30P4 |
60 |
2800 |
30 |
450 |
700 |
| LX-70450-30P4 |
70 |
3850 |
30 |
450 |
725 |
| Options |
|
|
|
|
|
|
-C |
Carbon Fiber Window, add-C to the model number |
|
-RB |
Reduced background PopTop
capsule with Carbon Fiber Endcap, add “-RB” to the model number [e.g.,
LX-36300-15P4-RB] |
|
-RB-B |
Reduced background PopTop
capsule with Be Window in Cu Endcap, add
“-RB-B” to the model number [e.g., LX-36300-15P4-RB-B] |
|
SMART-1-N |
SMART-1 detector option for negative bias
detector. To order, add
SMART-1-N as a separate line item. |
* All LO-AX PopTop detector capsules include sealed detector element,
preamplifier, high-voltage filter, and a 0.02 inch thick
Be window with diameter ≥ that
of the detector.
** FWHM = Full Width at Half Maximum; total system resolution for a
source at 1000 counts/s measured in accordance with ANSI/IEEE Std. 325-1996, using ORTEC
standard electronics. |