GEM High-Purity Germanium (HPGe) Coaxial Detectors
(in PopTop Capsule)

For computer-based analysis of complex spectra requiring the best in resolution, peak-to-Compton ratio, peak shape, and efficiency:
  • Large stocklist at all times
  • Efficiencies to 150%, higher on request
  • New "Application-Tuned" PROFILE Series available
  • PopTop flexibility
  • Excellent energy resolution
  • Excellent peak symmetry
  • Automatic high-voltage shutdown protects preamplifier input FET
  • Indicator warns of excessive counting rate
  • PLUS preamplifier option for ultra-high-rate applications
b8.jpg (20527 bytes)
Figure 8. Configurations of Coaxial Germanium Crystals.
GEM Series Germanium (HPGe) detectors are manufactured with ORTEC’s own Germanium and represent the state of the art in "conventional", i.e., outer contact Li diffusion and inner contact ion-implanted Germanium coaxial detectors (Fig. 8). Because of the superior quality of ORTEC’s Germanium material, GEM detectors feature the best available energy resolution, peak-to-Compton ratios, and peak symmetry ratios at 1.33 MeV. Note that energy resolution and symmetry ratios are warranted to two decimal places.

The high degree of symmetry resulting from the superior material and processes used in manufacturing ORTEC detectors make them ideal for computer-based analysis where the detector peak shape is of paramount importance.

ORTEC is renowned for delivering detectors with measured specifications substantially better than the warranted values.

The geometrical features of the GEM detector that result in such excellent peak shape are: (1) by far the world’s best germanium crystals, (2) deep holes used for making the central contact, (3) "bulletized" (rounded) front corners on the detector for uniform electric field. No one makes detectors as well as ORTEC.

ORTEC maintains a large stocklist of GEM detectors. Some of these have "super specifications," that is, a warranted energy resolution better than the first category GEM specifications.

Unless otherwise specified, each GEM HPGe coaxial detector is supplied in a PopTop capsule. A complete detector assembly requires a cryostat and a dewar.

Options of Interest Ordering Information

GEM Germanium (HPGe) Coaxial Detector (Non-PopTop or PopTop)

For GEM Detector in PopTop capsule, add "P4" to the model no. [e.g., GEM90P4-95].
Endcap diameter must be specified, see Endcap Diameter Options [e.g., GEM10-70,
    GEM35P4-76]
FW.02M/FWHM specification is Typical, all other specifications are warranted.
 
Model No. Efficiency (%) Resolution

Peak-to-Compton Ratio

Peak Shape* Endcap Diameter Options
@122 keV (keV) @1.33 MeV (keV) FW.1M/ FWHM FW.02M/**
FWHM
GEM150 150 1.30 2.3 90:1 2.0 3.1 -108
GEM140 140 1.30 2.2 90:1 2.0 3.1 -108
GEM130 130 1.30 2.1 90:1 2.0 3.1 -108
GEM120 120 1.30 2.1 86:1 2.0 3.1 -108
GEM110 110 1.30 2.1 85:1 2.0 3.0 -95
GEM100 100 1.20 2.1 83:1 2.0 3.0 -95
GEM90 90 1.20 2.0 80:1 2.0 3.0 -95
GEM80 80 1.10 2.0 77:1 2.0 3.0 -95
GEM75 75 1.10 2.0 77:1 2.0 3.0 -95
GEM70 70 1.00 2.0 75:1 2.0 3.0 -95
GEM65 65 1.00 1.95 73:1 1.9 3.0 -83, -95
GEM60 60 1.00 1.95 70:1 1.9 3.0 -83, -95
GEM55 55 1.00 1.90 67:1 1.9 2.8 -83
GEM50 50 0.90 1.90 66:1 1.9 2.6 -83
GEM45 45 0.90 1.90 64:1 1.9 2.6 -76, -83
GEM40 40 0.87 1.85 64:1 1.9 2.6 -76, -83
GEM35 35 0.85 1.85 62:1 1.9 2.6 -70, -76, -83
GEM30 30 0.85 1.85 60:1 1.9 2.6 -70, -76, -83
GEM25 25 0.82 1.85 56:1 1.9 2.6 -70, -76, -83
GEM20 20 0.82 1.80 52:1 1.9 2.6 -70
GEM15 15 0.82 1.80 46:1 1.9 2.6 -70
GEM10 10 0.80 1.75 41:1 1.9 2.6 -70
Options              
-RB Reduced background PopTop Capsule with Carbon Fiber Endcap, add "-RB" to the model number [e.g., GEM10P4-70-RB]
-PLUS Ultra-high-count-rate Preamplifier, add "-PLUS" to the model number [e.g., GEM10P-70-PLUS for PopTop or GEM10-70-PLUS for Non-PopTop]
SMART-1-P SMART-1 detector option for positive bias detector. To order, add SMART-1-P as a separate line item.

†All GEM PopTop detector capsules include sealed detector element, preamplifier, and high-voltage filter. Useful energy ranges, from 40 keV to 10 MeV.

*FWHM = Full Width at Half Maximum; FW.1M = Full Width at One-Tenth Maximum; FW.02M = Full Width at One-Fiftieth Maximum; total system resolution for a source at 1000 counts/s measured in accordance with ANSI/IEEE Std. 325-1996, using ORTEC standard electronics.

**Typical Value.

NOTE: For those familiar with HPGe detector specifications, you will notice that ORTEC now offers ONLY "first category" detector specifications. Recent process improvements now make this possible.