ULTRA and ULTRA-AS
The new standard for charged-particle detector spectroscopy ULTRA-AS Low-background version for alpha spectroscopyULTRA ion-implanted-silicon detectors for alpha and beta spectroscopy are the most advanced charged-particle detectors ever produced. They possess the reliability that has made ORTEC the sole supplier to NASA of silicon detectors for space applications. Both the entrance and the back contact are ion implanted. The entrance contact is an extremely thin (~500 Å) boron implantation. Since no epoxies are used to mount the ULTRAs, the distance between the silicon surface and the top of the mounting can is <1 mm; this provides maximum geometric efficiency. The rugged front contact, easily cleaned with a solvent-moistened cotton swab, is impervious to finger contact.ULTRA detectors have gold-plated mounting cans. The superior electrical conductivity of gold, which can never oxidize, makes it the choice vs. stainless steel or aluminum. Gold contacts last a lifetime. An advanced surface passivation that covers the critical silicon dioxide layer guarantees absolute device stability. The extremely low leakage current permits specifying the energy resolution at a 1-µs amplifier time constant.Low-background ULTRA-AS detectors are made with special low-background materials and have an optimized depletion thickness to minimize background counts from cosmic rays. All ORTEC Alpha Spectrometers (OCTÊTE Plus, 576A, and SOLOIST) are equipped with either ULTRA-AS detectors or R-Series, Ruggedized Surface Barrier Detectors. All these spectrometers, when equipped with a 450 mm2 detector, have a warranted background performance of £24 counts per day, over the 3- to 8-MeV energy range. The dimensions of the ULTRA and ULTRA-AS detector mounting cans, identical to those of the corresponding size A or R Series detectors, ensure that ULTRA detectors will fit perfectly in any application where A or R Series detectors are being used now.NOTE: Extensive care regarding detector and chamber cleanliness can result in background count levels as low as 0.05 counts/hr/cm2 of active area, corresponding to 6 counts/24 hours, for a 450 mm2 active area. ULTRA and ULTRA-AS detectors are normally supplied in "B" mount, with a rear Microdot connector. Other mounting arrangements are available on request. (Example: For horizontal samples in Model 576A NIM Spectrometers, a closed-back "T" mount with side-mounted Microdot connector is needed. See note below ULTRA and ULTRA-AS tables.)Dimensions and Mounting Arrangement
Ordering Information ULTRA Specify B or "Blind" T** Mount
ULTRA-AS Specify B or "Blind" T** Mount
*First three digits of Model No. indicate total system resolution FWHM for 241Am, 5.486-MeV alphas, using standard ORTEC electronics and 1-µs shaping time constants. **"Blind" T Mount available only for 300-, 450-, and 600-mm2, except by special order.To Order: Add the appropriate letter prefix for the mounting desired.Example: BU-016-300-100 or TU-016-300-100** |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||